Page 1 - VCA-E30AW

Use, Care, and Installation GuideModel number: Serial Number: DEC11.0101CascadeVCA-E30ASVCA-E30ABVCA-E30AW

Page 2

8Installation – Specifi cationselec.k/oTOP6” Round DuctingBACKSIDE27 13/16”2”8 5/8”12 3/16”3/4”4 3/16”6”10”2 3/4”5 7/8”5 7/8”7/8”elec.k/o10”3 1/4”11/16

Page 3

9ELECTRICALWARNINGAll Electrical work must by performed by qualifi ed electrician or person with similar technical know how and background.For personal

Page 4

1. Remove filters2. Remove cover from junction box to gain access to electrical wiring.3. If using a cable lock, pry open the desired electrical kno

Page 5

An air recirculating kit (optional) must be purchased before using hood in recirculat-ing mode.1. Secure each of the (2) spring clips to the safety g

Page 6

Installation – Converting to Air Recirculating Mode125. Remove each of the 5 screws holding the (2) interior recirculating panels.6. Remove (2) inte

Page 7

13For Mounting Under a Kitchen Cabinet (Fig 1)1. Select preferred duct location (vertical or horizontal) if ducting air out of kitchen. Refer to page

Page 8

14Features & Controls – Rocker ControlsThis switch turns the blower on and o and controls the speed selection.is o, is low speed andis high spee

Page 9

15SURFACE MAINTENANCE:Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouri

Page 10 - Installation – Specifi cations

16REPLACING LIGHT BULBSCAUTION: Light bulb becomes extremely hot when turned on.DO NOT touch bulb until switched off and cooled. Touching hot bulbs c

Page 11 - ELECTRICAL

Troubleshooting17TROUBLESHOOTING PROCEDURES FOR CASCADEIssue Cause What to doAfter installation, the unit doesn’t work.1. The power source is not tur

Page 13

Wiring Diagrams18

Page 14

19DESCRIPTION PART # Replacement PartsLight Bulb, MR16 GU10, 35W (each) Z0B0023

Page 15

Use, Care, and Installation GuideModel number: Serial Number: DEC11.0101CascadeVCA-E30ASVCA-E30ABVCA-E30AW

Page 17 - SURFACE MAINTENANCE:

1SAFETY NOTICE ... 2-3LIST OF MATERIALS ...

Page 18 - Maintenance – Lights

Important Safety NoticeREAD AND SAVE THESE INSTRUCTIONS2WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE

Page 19 - Troubleshooting

Important Safety Notice3WARNINGTO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.NOT FOR USE OVER AN OUTDOOR GRILL.CAUTIONTo reduce risk of fi re and

Page 20 - Wiring Diagrams

List of Materials4MODELS: VCA-E30AS, VCA-E30AB, VCA-E30AWPARTS SUPPLIED1 - Hood2 - Aluminum Mesh Filters2 - Halogen Light Bulbs (GU10, 35W)1 - 6” Roun

Page 21 - List of Parts and Accessories

5Installation – Ducting Calculation SheetDuct piecesTo t a lEquivalent numberlength x used =3-1/ 4” x 10”Rect.,straight1 Ft. x ( ) =

Page 22

Installation – Mounting Height & Clearance6DUCTINGA minimum 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow ef

Page 23

1SAFETY NOTICE ... 2-3LIST OF MATERIALS ...

Page 24 - Table of Contents

7WARNING FIRE HAZARDNEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be

Page 25 - Important Safety Notice

8Installation – Specifi cationselec.k/oTOP6” Round DuctingBACKSIDE27 13/16”2”8 5/8”12 3/16”3/4”4 3/16”6”10”2 3/4”5 7/8”5 7/8”7/8”elec.k/o10”3 1/4”11/16

Page 26

9ELECTRICALWARNINGAll Electrical work must by performed by qualifi ed electrician or person with similar technical know how and background.For personal

Page 27 - List of Materials

1. Remove filters2. Remove cover from junction box to gain access to electrical wiring.3. If using a cable lock, pry open the desired electrical kno

Page 28 - Total ductwork =

An air recirculating kit (optional) must be purchased before using hood in recirculat-ing mode.1. Secure each of the (2) spring clips to the safety g

Page 29 - Min 24” - Max 32"

Installation – Converting to Air Recirculating Mode125. Remove each of the 5 screws holding the (2) interior recirculating panels.6. Remove (2) inte

Page 30 - WARNING FIRE HAZARD

13For Mounting Under a Kitchen Cabinet (Fig 1)1. Select preferred duct location (vertical or horizontal) if ducting air out of kitchen. Refer to page

Page 31

14Features & Controls – Rocker ControlsThis switch turns the blower on and o and controls the speed selection.is o, is low speed andis high spee

Page 32

15SURFACE MAINTENANCE:Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouri

Page 33

16REPLACING LIGHT BULBSCAUTION: Light bulb becomes extremely hot when turned on.DO NOT touch bulb until switched off and cooled. Touching hot bulbs c

Page 34

Important Safety NoticeREAD AND SAVE THESE INSTRUCTIONS2WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE

Page 35

Troubleshooting17TROUBLESHOOTING PROCEDURES FOR CASCADEIssue Cause What to doAfter installation, the unit doesn’t work.1. The power source is not tur

Page 36

Wiring Diagrams18

Page 37

19DESCRIPTION PART # Replacement PartsLight Bulb, MR16 GU10, 35W (each) Z0B0023

Page 38

1-888-880-8368STAPLE YOUR RECEIPT HERETO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (refe

Page 39

1-888-750-1698STAPLE YOUR RECEIPT HERETO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Valore (referred to here

Page 40

Guide d’utilisation, d’entretien et d’installationNuméro de modèle Numéro de série: DEC11.0101CascadeVCA-E30ASVCA-E30ABVCA-E30AW

Page 42

1MISE EN GARDE DE SÉCURITÉ ... 2-3LISTE DU MATÉRIEL ... 4INSTALLATIONFeuil

Page 43 - Limited Warranty

Mise en garde de sécuritéLISEZ ET CONSERVEZ CES INSTRUCTIONS2AVERTISSEMENTPOUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PA

Page 44

Mise en garde de sécurité3ATTENTIONPOUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL.CET APPAREIL N’EST PAS CONÇU P

Page 45

Important Safety Notice3WARNINGTO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.NOT FOR USE OVER AN OUTDOOR GRILL.CAUTIONTo reduce risk of fi re and

Page 46

Liste du matériel4MODÈLES : VCA-E30AS, VCA-E30AB, VCA-E30AWPIÈCES FOURNIES1 - Hotte2 - Filtre à tamis en aluminium2 - Ampoules halogènes (GU-10 35W)1

Page 47 - Table des Matières

5Installation – Feuille de calcul pour le conduit d’aérationPièces de conduitTotalLongueur x Nombre utilisé 3-1/ 4” x 10”rect., droit1 pi x

Page 48 - Mise en garde de sécurité

Installation – Espace libre et hauteur de montage6CONDUIT D’AÉRATIONUn conduit circulaire de 6” ou rectangulaire de 3¼” x 10” doit être utilisé pour

Page 49

7AVERTISSEMENT DE RISQUE D’INCENDIEN’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le

Page 50 - Liste du matériel

8Installation – Entréedéfonçablepour élec.HAUTConduit circ. de 6"ARRIÈRECÔTÉ27 13/16”2”8 5/8”12 3/16”3/4”4 3/16”6”10”2 3/4”5 7/8”5 7

Page 51 - Total du conduit =

9ÉLECTRICITÉAVERTISSEMENTl’expérience technique et

Page 52 - CONDUIT D’AÉRATION

1. Enlevez les filtres. 2. Enlevez le couvercle de la boîte de connexion pour avoir accès au câblage électrique.3. Si vous utilisez un raccord de câ

Page 53 - Bouche d’aération de

Vous devez vous procurer un ensemble de recirculation d’air (optionnel) avant d’utiliser la hotte en mode de recirculation d’air.1. Fixez les deux at

Page 54 - Installation – 

Installation – Utilisation du mode de recirculation d’air 125. Enlevez les cinq (5) vis qui retiennent les deux (2) panneaux intérieurs de recirculat

Page 55 - AVERTISSEMENT

13Pour une installation sous une armoire de cuisine (Fig. 1)1. Déterminez l’emplacement désiré du conduit (vertical ou horizontal) si vous évacuez l’

Page 56

List of Materials4MODELS: VCA-E30AS, VCA-E30AB, VCA-E30AWPARTS SUPPLIED1 - Hood2 - Aluminum Mesh Filters2 - Halogen Light Bulbs (GU10, 35W)1 - 6” Roun

Page 57

14Commandes – Commandes à bascule0 0Allumer/Éteindre – Choix de vitesse Lumières : Éteintes/Veilleuse/AlluméesAllumer/Éteindre – Choix de vitesse Cet

Page 58

15ENTRETIEN DES SURFACESNettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas

Page 59 - Électricité

16REMPLACEMENT DES AMPOULESATTENTION : Les ampoules deviennent extrêmement chaudes lorsqu’allumées.Veuillez NE PAS les toucher avant de les avoir étei

Page 60

Dépannage 17PROCÉDURES DE DÉPANNAGE POUR LA HOTTE CASCADEProblème Cause SolutionAprès l’installation, l’appareil ne fonctionne pas.1. Le bloc d’alime

Page 61 - ENTRETIEN DES SURFACES

Entretien - Schéma de câblage186FKËPDGHFLUFXLWVModèleTensionConsommation d’énergieLampe : Ventilateur :PROTÉGÉ THERMIQUEMENT5HPDUTXHV&RQGHQVDWH

Page 62 - Entretien – Lumières

19DESCRIPTION Nº DE PIÈCEPièces de remplacementAmpoule MR16 GU10, 35W (chaque) Z0B0023

Page 63 - Dépannage

AGRAFEZ VOTRE REÇU ICIPOUR OBTENIR DU SERVICE SOUS GARANTIE OU POUR TOUTE QUESTION LIÉE À L’ENTRETIEN, veuillez communiquer avec nous au 1-888-750-169

Page 64 - Entretien - Schéma de câblage

5Installation – Ducting Calculation SheetDuct piecesTo t a lEquivalent numberlength x used =3-1/ 4” x 10”Rect.,straight1 Ft. x ( ) =

Page 65

Installation – Mounting Height & Clearance6DUCTINGA minimum 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow ef