1. Disconnect blower plug.
 5HPRYHVFUHZVIURPLQWHULRURIKRRGERG\
attaching single blower plate to top of hood
body. Remove single blower and single blower
plate.
3. Knock out rear plate B for rear rectangular rear
ducting or plate C for 8 inch round rear ducting.
C
This range hood is equipped standard with a 8” round vertical duct option. To convert from 8” round vertical to 8”
round horizontal ducting or 3-1/4” x 10” rectangular horizontal ducting please following the instructions below.
VERTICAL TO HORIZONTAL DUCTING CONVERSION
Installation – Single Blower Horizontal Ducting Conversion
B
 5HPRYHVFUHZVDWWDFKLQJEORZHUWREORZHU
plate. Turn blower 180 degrees and reattach to
blower plate.