Zephyr ZMD-E42AS Guide d'installation Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
13
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
IURPFRRNLQJDUHGUDZQDQG¿OWHUHGE\DVHWRIRSWLRQDOFKDUFRDO¿OWHUV7KHDLULVWKHQSXUL¿HGDQGUHFLUFXODWHG
back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work,
LISRVVLEOH7KHKRRGLVPRVWHIIHFWLYHDQGHI¿FLHQWDVDQH[KDXVWKRRG2QO\ZKHQWKHH[KDXVWRSWLRQLVQRW
possible should you recourse to converting the hood into a recirculating hood.
:KHQFRQYHUWHGWREHDUHFLUFXODWLQJKRRGDVHWRIFKDUFRDO¿OWHUVDUHUHTXLUHGRQWRSRILWVVWDQGDUG$OXPLQXP
Mesh Filter set. Order according to its Part number below. The standard Aluminum Mesh Filters are intended
WRFDSWXUHUHVLGXHIURPFRRNLQJDQGWKHRSWLRQDOFKDUFRDO¿OWHUVKHOSWRSXULI\IXPHVH[KDXVWHGIURPFRRNLQJ
for re-circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
.LWLQFOXGHVFKDUFRDO¿OWHUFKDUFRDO¿OWHUEUDFNHWDQGDLUGLYHUWHUSODWH
Hood Model Part No. Filters in Pkg.
ZMD-M90AS ZRC-00MD 1
ZMD-E42AS ZRC-00MD 1
1. Purchase recirculating kit per the part number above
 6HFXUHDLUGLYHUWHUSODWHWRWRSVXSSRUWIUDPH),*.5XQ´GXFWLQJ
from top of hood and secure to air diverter plate.
 5HPRYHDOXPLQXPPHVK¿OWHUIURPKRRG,QVWDOOFKDUFRDO¿OWHUEUDFNHW
LQVLGH ¿OWHU RSHQLQJ 1RWH VFUHZV WR VHFXUH FKDUFRDO ¿OWHU EUDFNHW
DUHDOUHDG\SUHLQVWDOOHGLQWKHKRRGDQGPXVW¿UVWEHUHPRYHG&OLS
FKDUFRDO¿OWHULQWRFKDUFRDO¿OWHUEUDFNHW),*.
5HLQVWDOODOXPLQXPPHVK¿OWHU
 7XUQRQFKDUFRDO¿OWHUFKDQJHLQGLFDWRURQFRQWUROSDQHOUHIHUWRGHWDLOV
RQSDJH7KHPLFURSURFHVVRULQWKHFRQWUROVZLOOLQGLFDWHWKHQHHG
WRFKDQJHWKHFKDUFRDO¿OWHUDIWHUKRXUVRIFRQWLQXRXVXVH2UGHU
UHSODFHPHQWFKDUFRDO¿OWHUVSHUWKHOLVWEHORZ
Note: Refer to manual included with recirculating kit for more detailed
installation instructions.
Charcoal Filter Replacements
Hood Model Part No. Qty to Order
ZMD-M90AS Z0F-C002 1
ZMD-E42AS Z0F-C002 1
'2127:$6+&+$5&2$/),/7(56&KDUFRDO¿OWHUVPD\QHHG
to be changed more often depending on cooking habits.
Installation – Ductless Recirculating
FIG. K
Vue de la page 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 47 48

Commentaires sur ces manuels

Pas de commentaire