Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
NOV12.0301 © Zephyr Corporation
READ AND SAVE THESE INSTRUCTIONS
CACHE
CCA-E30ASX
CCA-E36ASX
CCA-E48ASX
Vue de la page 0
1 2 3 4 5 6 ... 22 23

Résumé du contenu

Page 1 - CCA-E48ASX

Use, Care, and Installation Guidewww.zephyronline.comModel number: Serial Number: Date of Purchase: Sales Dealer: NOV12.0301 © Zephyr CorporationREAD

Page 2

8www.zephyronline.comInstallation – Hood Specifi cations27-7/8” - (30“), 33-7/8” - (36“), 45-53/64 - (48”)29-61/64” - (30“), 35-61/64” - (36“), 47-

Page 3 - Table of Contents

9ELECTRICALWARNINGAll Electrical work must by performed by qualifi ed electrician or person with similar technical know how and background.For personal

Page 4 - Important Safety Notice

10www.zephyronline.comINTERNAL BLOWER PREPARATION – VERTICAL DUCTING1. Attach capacitor box to inside of hood using two M4*10 screws included with in

Page 5

117. Connect 9 pin male connector from blower to 9 pin female connector on capacitor box.Installation – Internal Blower (Vertical Ducting)

Page 6 - List of Materials

12www.zephyronline.comInstallation – Internal Blower (Horizontal Ducting)1. Attach capacitor box to inside of hood using two M4*10 screws included wi

Page 7 - Total ductwork =

137. Place blower over round to rectangular adapter as shown above.8. Install blower with round to rectangular adapter into hood.Installation – Inte

Page 8 - 32” max

14www.zephyronline.comInstallation – External Blower Preparation3. Place cap over threaded cable lock and secure by turning cap clockwise. NOTE: Due

Page 9 - WARNING FIRE HAZARD

15 Hood is designed for installation under a kitchen cabinet1. Select preferred duct location (internal blower -vertical or horizontal, external

Page 10 - Side View

16www.zephyronline.com Blower On/OffBy pressing , the blower is switched On and Off. When switched on, the blower starts up onthe same speed

Page 11 - Cable Lock

17Features & Controls – FeaturesBaffle Filter Clean Reminder Whether your hood is installed as an exhaust or purifying unit, a set if baffle filte

Page 12

www.zephyronline.com

Page 13

18www.zephyronline.comSURFACE MAINTENANCE:Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent,

Page 14

19REPLACING LIGHT BULBSCAUTION: Light bulb becomes extremely hot when turned on.DO NOT touch bulb until switched off and cooled. Touching hot bulbs co

Page 15

Troubleshooting20www.zephyronline.comTROUBLESHOOTING PROCEDURES FOR CACHEIssue Cause What to doAfter installation, the unit doesn’t work.1. The power

Page 16 - EXTERNAL BLOWER PREPARATION

1-888-880-8368STAPLE YOUR RECEIPT HERETO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (refe

Page 17

1SAFETY NOTICE ... 2-3LIST OF MATERIALS ...

Page 18

Important Safety NoticeREAD AND SAVE THESE INSTRUCTIONS2www.zephyronline.comWARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN

Page 19

Important Safety Notice3CAUTIONTo reduce the risk of fi re and electric shock, install this range hood only with external blower models CBE-1000, rated

Page 20 - SURFACE MAINTENANCE:

List of Materials4www.zephyronline.comMODEL: CCA-E30ASX, CCA-E36ASX, CCA-E48ASX1 - Hood2 - Baffl e fi lters (3) for 48” model2 - Halogen light bulbs (4)

Page 21 - Maintenance – Lights

5Duct pieces Tot a lEquivalent numberlength x used =3- 1/ 4” x 10”Rect.,straight1 Ft. x ( ) =Ft. 8” Round,straight1 Ft.

Page 22 - Troubleshooting

Installation – Mounting Height & Clearance6www.zephyronline.comDUCTINGA minimum of 6” round or 3-1/4” x 10” rectangular duct work must be used to

Page 23 - STAPLE YOUR RECEIPT HERE

7WARNING FIRE HAZARDNEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be