Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
SEP07.0101 © Zephyr Corporation
Tempest I
AK7000AS
AK7036AS
AK7042AS
READ AND SAVE THESE INSTRUCTIONS
Vue de la page 0
1 2 3 4 5 6 ... 22 23

Résumé du contenu

Page 1 - Tempest I

Use, Care, and Installation Guidewww.zephyronline.comModel number: Serial Number: Date of Purchase: Sales Dealer: SEP07.0101 © Zephyr CorporationTempe

Page 2

8www.zephyronline.comInstallation – Specifi cations1 3/16”89/16”13/16”23/16”2 3/4”3”277/8” (30”)337/8” (36”)3913/16” (42”)2915/16” (30”)3

Page 3 - Table of Contents

9ELECTRICALWARNINGAll Electrical work must by performed by qualifi ed electrician or person with similar technical know how and background.For personal

Page 4 - Important Safety Notice

10www.zephyronline.comInstallation – Mounting the Range HoodFor dual blower installation instructions please refer to page 13.For Mounting Under a Kit

Page 5

11This range hood is equipped standard with a 6” round vertical duct option. To convert from 6” round vertical to 3-1/4” x 10” horizontal ducting ple

Page 6 - List of Materials

12www.zephyronline.com6. On the back of the hood, remove the (6) screws holding the rectangular cap. 7. Place round to rectangular transition adap

Page 7 - Total ductwork =

131. Disconnect single blower wire.2. Remove support screw from top of hood near the back. Remove 2 screws holding blower plate to hood and pull blo

Page 8 - Min 26” - Max 36"

14www.zephyronline.comInstallation – PBD-1100A Dual Blower7. Secure dual blower plate to hood by following removal instructions in reverse. Attach bl

Page 9 - WARNING FIRE HAZARD

15Accessory Installation – Heat Lamp Kit1. Remove nuts from each of the (4) screws around the bottom panel. Remove bottom panel.2. Replace bottom pa

Page 10 - Installation – Specifi cations

16www.zephyronline.comFeatures & Controls – Touch Controls & FeaturesBlower On/OffBy pressing , the blower is switched On and Off. When s

Page 11 - ELECTRICAL

17SURFACE MAINTENANCE:Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouri

Page 12

www.zephyronline.com

Page 13

18www.zephyronline.comREPLACING LIGHT BULBSCAUTION: Light bulb becomes extremely hot when turned on.DO NOT touch bulb until switched off and cooled. T

Page 14

Troubleshooting19TROUBLESHOOTING PROCEDURES FOR TEMPEST I AND TEMPEST IIIssue Cause What to doAfter installation, the unit doesn’t work.1. The power

Page 15 - DUAL BLOWER INSTALLATION*

20www.zephyronline.comDESCRIPTION PART # Replacement PartsLight Bulb MR16 (GU10) 35W (each) Z0B-0015Baffl e Filter (e

Page 16

WarrantyTO OBTAIN SERVICE UNDER WARRANTY:or any Service Related Questions, please call:1-888-880-8368Staple your receipt here.Proof of the original pu

Page 17 - HEAT LAMP KIT INSTALLATION*

1SAFETY NOTICE ... 2-3LIST OF MATERIALS ...

Page 18

Important Safety NoticeREAD AND SAVE THESE INSTRUCTIONS2www.zephyronline.comWARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN

Page 19 - SURFACE MAINTENANCE:

Important Safety Notice3WARNINGTO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.CAUTIONTo reduce risk of fi re and to properly exhaust air outside -

Page 20 - Maintenance – Lights

List of Materials4www.zephyronline.comMODELS: AK7000AS, AK7036AS, AK7042ASPARTS SUPPLIED1 - Hood2 - Baffl e fi lters (3 - AK7036AS and AK7042AS)2 - Halo

Page 21 - Troubleshooting

5Installation – Ducting Calculation SheetDuct piecesTo t a lEquivalent numberlength x used =3-1/ 4” x 10”Rect.,straight1 Ft. x ( ) =

Page 22 - List of Parts and Accessories

Installation – Mounting Height & Clearance6www.zephyronline.comDUCTINGA minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maint

Page 23 - Warranty

7WARNING FIRE HAZARDNEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be