Vue de la page 12
11
1. Disconnect blower plug.
2. Remove (4) screws from interior of hood body
attaching single blower plate to top of hood
body. Remove single blower and single blower
plate.
3. Knock out rear plate B for rear rectangular rear
ducting or plate C for 8 inch round rear ducting.
C
This range hood is equipped standard with a 8” round vertical duct option. To convert from 8” round vertical to 8”
round horizontal ducting or 3-1/4” x 10” rectangular horizontal ducting please following the instructions below.
VERTICAL TO HORIZONTAL DUCTING CONVERSION
Installation – Single Blower Horizontal Ducting Conversion
B
4. Remove (4) screws attaching blower to blower
plate. Turn blower 180 degrees and reattach to
blower plate.