Zephyr ZMI-M90AS Manuel d'utilisateur Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
10
www.zephyronline.com
(blower
housing)
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
from cooking are drawn and ltered by a set of optional charcoal lters. The air is then puri ed and re-
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
work, if possible. The hood is most effective and ef cient as an exhaust hood. Only when the exhaust option
is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal lters are required on top of its standard Metal
Filter set. Order according to its Part number below. The standard Metal Filters are intended to capture
residue from cooking and the optional charcoal lters help to purify fumes exhausted from cooking for re-
circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
Kit includes charcoal lters and air diverter plate.
Hood Model Part No. Filters in Pkg.
ZMI-M90AG/AS ZRC-0040 2
1. Purchase recirculating kit per the part number above
2. Secure air diverter plate to wall below duct cover bracket. (FIG. B)
Run 6” ducting from top of hood and secure to air diverter plate. See
manual included with recirculating kit for more detailed instructions.
3. Remove metal mesh lters from hood. Clip charcoal lters onto each
charcoal lter bracket. (FIG. C) The brackets are pre-installed and
located beind the mesh lters.
4. Re-Install metal mesh lters.
5. Enable charcoal lter change indicator on control panel. (Refer details to pg. 12)
6. Charcoal lters must be replaced after every 120 hours of use (or
approximately every 3 to 4 months based on the average of 1 - 2 hrs.
of daily cooking time). The microprocessor in the controls when set,
will elapse and count usage time and indicate when charcoal lter
replacement is required every 120 hrs.
Charcoal Filter Replacements
Hood Model Part No. Qty to Order
ZMI-M90AS/AG Z0F-C002 2
DO NOT WASH CHARCOAL FILTERS. Charcoal lters may need
to be changed more often depending on cooking habits.
Charcoal Filter Dimensions:
9in x 6 3/8in
228mm x 162mm
Installation – Ductless Recirculating
D
E
Install charcoal filter (plastic side exposed)
into charcoal filter bracket. Insert tab
cut-out side D of charcoal filter into bracket
first. Lock charcoal filter into place by
pushing down on side E with locking tabs.
front of the hood
back of the hood
FIG. C
FIG. B
Vue de la page 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Commentaires sur ces manuels

Pas de commentaire